Technical specifications |
Sunny Tripower 20000TL |
Sunny Tripower 25000tl |
Input (DC) |
|
|
|
|
Max. DC power (with cos φ = 1) / Rated performance (DC) |
20440 W / 20440 W |
25550 W / 25550 W |
Max. Input voltage |
1000 V |
1000 V |
MPP voltage range / design input voltage |
320 V to 800 V / 600 V |
390 V to 800 V / 600 V |
Min. Input voltage / start input voltage |
150 V / 188 V |
150 V / 188 V |
Max. Input current input A / input B |
33 A / 33 A |
33 A / 33 A |
Number of independent MPP inputs / strings per MPP input |
2 / A: 3; B: 3 |
2 / A: 3; B: 3 |
Output (AC) |
|
|
|
|
Rated power (at 230 V, 50 Hz) |
20000 W |
25000 W |
Max. AC certificate |
20000 VA |
25000 VA |
AC nominal voltage |
3 / N / PE; 220 V / 380V 3 / N / PE; 230 V / 400 V 3 / N / PE; 240 V / 415 V |
AC voltage range |
180 V to 280V |
AC mains frequency / area |
50 Hz / 44 Hz to 55 Hz 60 Hz / 54 Hz to 65 Hz |
Rated network frequency / Rated network voltage |
50 Hz / 230 V |
Max. Output current / design output current |
29 A / 29 A |
36.2 A / 36.2 A |
Power factor at design power / displacement factor adjustable |
1/0 excised up to 0 underfered |
THD |
≤ 3 % |
Info periods / connection phases |
3 / 3 |
Efficiency |
|
|
|
|
Max. Efficiency / Europe. Efficiency |
98,4 % / 98,0 % |
98,3 % / 98,1 % |
safety devices |
|
|
|
Inside-side free switching point |
● |
Ground fault monitoring / network monitoring |
● / ● |
Integrable DC overvoltage arrester type II |
○ |
DC reverse polarity protection / AC short-circuit resistance / galvanic isolated |
● / ● / — |
All flow sensitive residual current monitoring unit |
● |
Protection class (according to IEC 62109-1) / Overvoltage category (according to IEC 62109-1) |
I / AC: III; DC: II |
General data |
|
|
|
Dimensions (B / H / T) |
661/682/264 mm (26.0 / 26.9 / 10.4 inch) |
Weight |
61 kg (134.48 lb) |
Operating temperature range |
-25 ° C to +60 ° C (-13 ° F to +140 ° F) |
Noise emission, typical |
51 dB (A) |
Own consumption (night) |
1W |
Topology / Cooling Principle |
Transformerless / Opticool |
Degree of protection (according to IEC 60529) |
IP65 |
Climate class (according to IEC 60721-3-4) |
4k4h |
Permissible maximum value for the relative humidity (not condensing) |
100 % |
Equipment / Function / Accessories |
|
|
|
DC connection / AC connection |
Sunclix / spring clamp |
Display |
● |
Interface: RS485, Speedwire / WebConnect |
○ / ● |
Data interface: SMA Modbus / SunSpec Modbus |
● / ● |
Multifunction relay / Power Control module |
○ / ○ |
Optitrack Global Peak / Integrated Plant Control / Q on Demand 24/7 |
● / ● / ● |
Off-Grid capable / SMA Fuel Save Controller compatible |
● / ● |
Manufacturer's warranty 2): 5/10/15/20 years |
● / ○ / ○ / ○ |
Certificates and approvals (more on request) * Does not apply to all national annexes of EN 50438 |
In 30, 25, bdft 2008, CDO8, CDKE 2008, CDs / 18-16, a 50-21, an 50-21, an 50-21, ef 4-21, an 50/438: 2011, so, there G59 / 3, IEC 60068-2-X, IEC 6127, ICM209-1 / 2, ENB27, NBA 2019, RDC, RDR 1693 , Rd 661/2007, res. N ° 7: 2013, Sur.777, TR4, TR 3.2,2,2,2,2,2,712-1, Vde 0126-1-1, VFR 2010 |
|
|
|
Types' Type |
STP 20000tl-30 |
STP 25000tl-30 |