Fronius Primo-5.0-1 Inverter Solar Primo-5.0-1 4.210.063
Fronius

Fronius Primo-5.0-1 Solar Inverter PRIMO-5.0-1 4.210.063

Regular price €1,151.18 €0.00
Fronius Primo-5.0-1 Solar Inverter PRIMO-5.0-1
The successor of Fronius IG Plus 55V-1 Solar inverter


!!not for DE-suited!!

The communicative inverter for optimised energy management.

With power categories from 3.0 to 8.2 kW, rounded to the Fronius Primo the new SnapINverter generation perfectly. The single-phase, transformerless device is the ideal inverter for private households.

The Fronius Primo has an exceptionally large input voltage range - maximum flexibility in the plant design is safe. In the case of single-phase systems it is the perfect Repowering inverter.

Technical Data


Input data Fronius Primo 5.0-1 Fronius Primo 5.0-1
Max. Input current
(Idc max 1 / Idc max 2 )
12.0 A / 12.0 A 18.0 A / 18.0 A
Max. Short-Circuit Current Module Field
(MPP1/MPP2)
18.0 A / 18.0 A 27,0 A / 27,0 A
Min. Input voltage
(Udc min)
80 V
Feed-In Start Voltage (Udc start) 80 V
Nominal Input Voltage (Udc,r) 710 V
Max. Input Voltage (Udc max) 1,000 V
MPP voltage range (Umpp min - Umpp max) 240 - 800 V
Number of MPP trackers 2
Number of DC connections 2+2
Max. PV-generator power (Pdc max) 7.5 kWpeak
Output data    
AC-nominal power (Pac,r) 5,000 W 4.600 W
Max. Output power 5.000 VA 5.000 VA
AC output current (Iac nom) 21.7 A 21.7 A
Grid Connection (Voltage Range) 1 ~ NPE 220 V / 230 V (180 V - 270 V)
Frequency (Frequency Range) 50 Hz / 60 Hz (45 - 65 Hz)
Total harmonic distortion < 5 %
Power factor (cos φac,r) 0,85 - 1 ind. / cap.
GENERAL DATA    
Dimensions (height x width x depth) 645 x 431 x 204 mm
Weight 21.5 kg
Degree of protection IP 65
Protection class 1
Overvoltage category (DC / AC)1) 2 / 3
Night consumption < 1 W
The inverter concept Transformerless
Cooling Controlled Air Cooling
Assembly Indoor and outdoor installation
Ambient Temperature Range -40 - +55 °C
Permissible Humidity 0 - 100 %
Max. Height above sea level 4,000 m
Connection technology DC 4x DC+ and 4x DC-screw terminals 2.5 - 16 mm2
Connection technology AC 3-pin AC screw terminals 2.5 - 16 mm2
Certificates and compliance with standards DIN V VDE 0126-1-1/A1, IEC 62109-1/-2, IEC 62116, IEC 61727,<br /> AS 4777-2, AS 4777-3, G83/2, G59/3, CEI 0-21, VDE AR N 4105 2)
EFFICIENCY    
Max. Efficiency 98,0 % 98,0 %
Europ. Efficiency (ηEU) 97,1 % 97,1 %
η at 5 % Pac,r3) 80,8 / 82,5 / 82,5 % 80,8 / 82,5 / 82,5 %
η at 10 % Pac,r3) 89,6 / 94,8 / 93,1 % 89,6 / 94,8 / 93,1 %
η at 20 % Pac,r3) 93,4 / 97,2 / 96,2 % 93,4 / 97,2 / 96,2 %
η at 25 % Pac,r3) 94,1 / 97,3 / 96,8 % 94,1 / 97,3 / 96,8 %
η at 30 % Pac,r3) 94,7 / 97,4 / 97,0 % 94,7 / 97,4 / 97,0 %
η at 50 % Pac,r3) 95,8 / 97,9 / 97,7 % 95,8 / 97,9 / 97,7 %
η at 75 % Pac,r3) 96,1 / 98,0 / 97,9 % 96,1 / 98,0 / 97,9 %
η is 100 % Pac,r3) 96,2 / 97,9 / 97,9 % 96,2 / 97,9 / 97,9 %
MPP Adaptation efficiency > 99.9% of
Protection facilities    
DC insulation measurement

Share this Product


More from this collection